Full-Process Patient QA Software
Master is our intelligent plan verification platform specifically designed for radiotherapy patient QA. Centered around treatment plans, EPID, and logfiles, it integrates advanced technologies such as iterative back-projection, Collapsed Cone Convolution Superposition (CCCS) / Monte Carlo algorithms, and GPU acceleration. This platform streamlines the entire workflow from "secondary dose verification - pre-treatment validation - intra-treatment monitoring - Fraction-by-Fraction Dose Monitoring" workflow. Compatible with multiple machine types and radiotherapy techniques, it delivers precise, efficient, and flexible dose verification solutions for clinical practice.

Compatible with

  • Full-Process Plan QA:
    Pre-Treatment Secondary Dose Checks
    Pre-Treatment 2D/3D Dose Verification
    Intra-Treatment 2D/3D In-Vivo Monitoring
    Fraction-based Dose Monitoring based on LINAC logfiles
  • RT Techniques:
    IMRT
    VMAT
    SBRT
    SRS, etc.
    Also accommodates dose accuracy requirements for advanced techniques like high-dose-rate (FFF) and ultra-fine MLC
  • Supports Multi-Center and Medical Consortium QA:
    Enable local/cloud deployment for centralized cross-hospital quality control data management
    Align with unified standards for medical consortiums and centralized multi-center test data management
  • Supports Adaptive Radiotherapy QA:
    Integrates CBCT with pseudo-CT reconstruction for real-time monitoring of tumor dose changes, enabling adaptive/dose-guided radiotherapy
  • Multi-Brand LINAC Compatibility:
    Elekta (Harmony Pro, Synergy, Infinity)
    Varian (Edge, VitalBeam, TrueBeam), etc.
    Flexible adaptation to hospital room layouts and treatment technology upgrade requirements

Key Features

  • Reducing Uncertainties Compared to Using Array
    Reducing Uncertainties Compared to Using Array
    Reduces positioning errors of detector arrays and human intervention errors.

    Reduces errors caused by organ displacement and motion (EDose supports in-vivo verification).
  • Enables the Automated Execution of Verification, Saving Working Time
    Enables the Automated Execution of Verification, Saving Working Time
  • Uses Water Phantom Data to Build the Model, Making the Energy Model More Closely Aligned with Standard Reference Values
    Uses Water Phantom Data to Build the Model, Making the Energy Model More Closely Aligned with Standard Reference Values
  • EDose Provides Multiple Types of Data Such As Logfile, DVH, Gamma, etc. to Assist in Comprehensive Analysis
    EDose Provides Multiple Types of Data Such As Logfile, DVH, Gamma, etc. to Assist in Comprehensive Analysis
  • Technical Parameters

    • Detector Type
      Ionization Chamber
    • Detector Quantity
      759
    • Detector Volume
      0.051cm³
    • Detector Spacing
      2mm (Min)
    • Nominal Sensitivity
      2.2nc/Gy±0.2nc/Gy
    • Field Size
      30mm × 30mm
    • Repeatability
      ≤±0.5%
    • Non-linearity
      ≤±0.5%
    • Dimensions(L×W×H)
      435mm×341mm×22mm
    • Weight
      5kg